Valveadjustment
Valve adjustment should be done with the control knob set at Burner ON saving ame po-
sition.
Remove the knob, and adjust the ame with a tiny screwdriver (see g. 7 below).
Fig. 7
Checking the adjusted ame: heat the burner at full open position for 10 minutes. Then turn
the knob into the saving setting. The ame should not extinguish nor move to the nozzle. If
it goes off or moves over to the nozzle, readjust the valves.
Note.
It is up to the used to request converting the appliance to another gas type if so
required by the local conditions at a licensed gas tter / service.